System Building
Static handling - pre-fabricated part planning for armoured concrete and prestressed concrete
Calculation of armoured concrete and prestressed concrete headers according to DIN 1045-1
- Untensioned reinforced roof trusses with parallel chords / gable end roof with partial and full post-tensioning
- Optional profile types with variable recesses, nominal width of transverse force bearing capacity
- Stresses and strains in transverse joist direction are also taken into consideration as well as torsion creating excentric strains
- Tilting confirmation under applicable registration of torsion rigidity according to Theory II Order
- Calculation of Theory II Order taking into consideration actual load and profile developing
- Bearing capacity calculations for bevel bending with normal force
- Bending calculation for Status II influenced by expansion and contraction
- Determination of distortion course from point in time To - Too, contortion, torsion moments
- Confirmation of tension force initiation, fasting and crack reduction for normal (C50/60) and high performance concrete (C55/67 to C100/115)
- Fire protection confirmation according to DIBT (German Institute for Building Technology) guideline
Detailed dimensioning in armoured concrete system building according to DIN 1045-1
- Consoles and recess areas
- Clevis bearing, confirmation of storage and lifting accessories